Experimental flow visualization and thermal-hydraulic characterization of local heating effects in a molten salt natural circulation loop $^{\star}$

Thomas Carson $^{a}$ $^{id,*}$ , Hansol Kim $^{a}$ , Joseph Seo $^{a}$ , Theodore Kupper $^{b}$ $^{id}$ , Cole Gentry $^{c}$ $^{id}$ , Kevin Clarno $^{c}$ $^{id}$ , Yassin Hassan $^{a,b}$

$^{a}$ Department of Nuclear Engineering, Texas A&M University, College Station, 77845, TX, United States of America

$^{b}$ Department of Mechanical Engineering, Texas A&M University, College Station, 77845, TX, United States of America

$^{c}$ Department of Mechanical Engineering, University of Texas, Austin, 78712, TX, United States of America

ARTICLE INFO

Keywords: Molten salt thermal-hydraulics Natural circulation Near-wall boundary-layer dynamics Particle Imaging Velocimetry (PIV)

ABSTRACT

As the primary mechanism of passive heat removal in nuclear reactors, understanding natural circulation is paramount to their safe operation and shutdown conditions. Natural circulation in molten salt reactors is of particular relevance due to the fluid's high Prandtl number as well as the phase of the fissile material in liquid-fueled reactors. Natural circulation loops are employed to study the thermal-hydraulic behavior of fluids when subject to thermal gradients and small flow disturbances. The objective of this work is to introduce and analyze the experimental effects of local heating conditions on the velocity profile and near-wall behavior of molten salts in a heated transparent test section. The study combines experimental PIV measurements with thermal-hydraulic characterization of the same natural-circulation operating states. Particle image velocimetry (PIV) was performed, and the boundary layer was analyzed for three different heating conditions. Those conditions were applied to the transparent test section: a cooling test condition, a thermally isolated test condition, and a heated test condition. In addition, the other thermal conditions of the loop were held constant. As the test section is heated, the peak velocity and slope of the velocity profile increase with test section heater power.

1. Introduction

1.1. Molten salt reactors

Molten salt reactors (MSRs) are Generation IV nuclear reactor designs that utilize a salt mixture as a coolant. In many MSR concepts, the fissile material is dissolved directly into the molten salt, forming a liquid-fueled system (U.S. NRC, 2018; ANS, 2024; Magnusson et al., 2020). This configuration provides several design advantages. Online fuel processing enables continued reactor operation during refueling, and continuous fission product removal increases achievable fuel burnup while reducing the need for excess reactivity in the core design. Some advanced concepts instead consider solid-fueled, salt-cooled configurations. As reactor coolants, molten salts are attractive because their relatively large volumetric heat capacity can reduce the required bulk temperature rise or mass flow rate for a given thermal duty. Heat removal performance, however, is not determined by heat capacity alone; it depends on the coupled effects of thermal conductivity, viscosity, density, flow velocity, heat-exchanger design, core geometry, and imposed boundary conditions. Additionally, low vapor pressure and high boiling temperature improve thermal margin and reduce pressurization requirements (Magnusson et al., 2020).

Despite these advantages, molten salts present unique challenges. Although they have been investigated for decades, their thermophysical properties are not as comprehensively characterized as those of water. Property variations arise from strong dependence on salt composition, chemical purity, and temperature. Even with controlled composition, significant temperature dependence of viscosity, density, and thermal conductivity complicates predictive modeling and experimental interpretation (Magnusson et al., 2020).

1.2. Regulatory relevance

The deployment of advanced reactors, including molten salt reactors (MSRs), depends on evolving regulatory frameworks that emphasize risk-informed, performance-based methodologies and early engagement with licensing authorities (Kim, 2023; U.S. NRC, 2020; U.S. DOE, 2024). Recent NRC regulatory guides and ANSI/ANS standards extend beyond traditional light-water reactor paradigms to address design characteristics unique to MSRs, including liquid fuel systems, online fission product removal, and containment of highly radioactive salt (U.S. NRC, 2018; ANS, 2024). Computational modeling, verification, and validation standards play an increasingly important role in demonstrating safety margins and informing design decisions; however, current practices remain constrained by limited MSR-specific experimental data and incomplete validation of mechanistic thermal-fluid models (Schultz and Crane, 2012). More recent molten-salt natural-circulation experiments and code-validation studies have reduced this gap for selected facilities and operating regimes, including FLiBe and nitrate-salt loops, system-code validation, and CFD analyses of distributed heating and high-Prandtl-number effects (Britsch et al., 2019; Battistini et al., 2021; Zou et al., 2021; Zhang et al., 2023; Reis et al., 2024b; Reis and Hassan, 2025; Missaglia et al., 2025).

Collectively, these regulatory and computational efforts define the criteria and analytical frameworks required for licensing, yet a critical gap persists in the experimental characterization of localized transient thermal-hydraulic behavior within molten salt systems. Flow visualization of transient local heating effects using full-field and near-wall PIV provides high-resolution measurements of mixing, shear development, and boundary-layer dynamics that are not accessible through bulk instrumentation. Such measurements supply the experimental evidence necessary to validate and refine safety analyses for advanced molten salt reactors under reactor-relevant conditions.

1.3. Literature survey - Natural circulation

Natural circulation loops (NCLs) have been extensively studied for their behavior, stability, and benchmarking in both water-based and molten salt systems, with applications in advanced reactors and passive safety design. Foundational investigations established the mechanisms of buoyancy-driven flow initiation, scaling relationships, and oscillatory instabilities (Creveling et al., 1975; Vijayan and Austregesilo, 1994; Vijayan, 2002). Subsequent experimental and analytical studies examined the influence of loop geometry, heater and cooler orientation, and wall thermal inertia on steady-state performance and stability characteristics (Kumar et al., 2011; Srivastava et al., 2015, 2022; Misale, 2014). High-temperature facilities, including the UW FLiBe loop (Britsch et al., 2019) and VESIL (Abou-Jaoude et al., 2021), demonstrated the feasibility of salt-based natural circulation systems, while the DYNASTY program provided detailed insight into distributed heating effects, stratification, and unstable transients (Battistini et al., 2021; Benzoni et al., 2024; Missaglia et al., 2025). Stability analyses further identified the roles of inclination, localized pressure losses, and coupled-loop interactions in determining dynamic behavior (Krishnani and Basu, 2017; Nadella et al., 2018; Nair et al., 2019; Novarese et al., 2024).

Transient investigations addressing startup, loss-of-heat-sink, and heater failure scenarios emphasized the nonlinear behavior of molten salts, including risks of solidification, flow blockage, and bubble recirculation (Kudariyawar et al., 2016; Srivastava et al., 2015; Reis et al., 2024a; Carson, 2025). Complementary CFD analyses highlighted the influence of internal heat generation and high-Prandtl-number effects on thermal development and flow structure (Jeong et al., 2018). Benchmarking efforts using system-level codes such as RELAP5 and SAM validated numerical predictions against facility-scale data but underscored the importance of accurate salt-specific friction factors, representative bulk temperature measurements, and proper accounting for buoyancy and radiative heat transfer (Zou et al., 2021; Zhang et al., 2023; Zhang and Sun, 2023; Reis and Hassan, 2025).

Collectively, this body of work establishes a foundation for understanding natural circulation in molten salts, while revealing persistent limitations in resolving localized thermal-hydraulic phenomena under reactor-relevant conditions. Although comprehensive steady-state flow visualization of molten salt behavior has been reported (Reis et al., 2024b), high-fidelity measurements of local velocity fields and boundary-layer development during transient conditions remain limited. Flow visualization of transient local heating effects using full-field and near-wall PIV provides the experimental resolution necessary to quantify these localized dynamics and reduce uncertainty in high-Prandtl-number molten salt behavior.

1.4. Modeling efforts & digital twin efforts at UT Austin

Modeling efforts supporting MSR deployment span dynamic system simulations, high-fidelity physics-based models, and emerging data-driven optimization frameworks. System-level thermal-hydraulic codes such as RELAP5 and SAM are used to evaluate transient response, passive safety characteristics, and accident progression in molten salt configurations (Zou et al., 2021; Reis and Hassan, 2025). In parallel, high-fidelity computational fluid dynamics (CFD) models are developed and validated or compared against experimental data to resolve complex flow phenomena, including stratification, distributed heating, high-Prandtl-number effects, and multiphase bubble dynamics that are not captured in one-dimensional formulations (Battistini et al., 2021; Jeong et al., 2018). Here, high-fidelity simulations refer primarily to CFD approaches such as Reynolds-Averaged Navier–Stokes and Large-Eddy Simulation, rather than empirical parameter tuning of reduced-order models. Efforts towards supporting integrated simulation and digital-twin frameworks couple physics-based models with operational data to support system design and real-time analysis (Villarreal et al., 2024; Fierro Lopez et al., 2025). Recent machine-learning-enhanced drift-flux modeling of bubbles in molten salt natural circulation further demonstrates the integration of data-driven approaches with mechanistic two-phase flow formulations for molten salt bubbly flow systems in supporting digital twin efforts (Villarreal, 2025).

To ensure that such modeling approaches are credible for licensing and safety assessment, structured verification and validation methodologies are required. The Evaluation Model Development and Assessment Process (EMDAP), as formalized in NRC Regulatory Guide 1.203, establishes a framework for systematic model development, benchmarking against experimental data, and uncertainty quantification to support regulatory acceptance of advanced simulation tools (U.S. Nuclear Regulatory Commission, 2005). Despite these advances, the predictive capability of both system-level and CFD-based models remains constrained by limited high-resolution experimental data under transient conditions. The present work employs experimental flow visualization of near-wall transient heating events to provide validation-relevant data by resolving localized shear development, boundary-layer evolution, and temperature–velocity coupling. These measurements directly inform boundary condition specification, improve turbulence and heat-transfer closure development, and strengthen reduced-order models and digital twins for advanced molten salt systems.

2. Experimental setup

2.1. Salt selection

Different salt compositions, including fueled and unfueled salts, can exhibit substantially different flow and heat-transfer behavior. Surrogate fluids therefore play an important role in isolating thermal-hydraulic phenomena before experiments are extended to higher-temperature or chemically hazardous salts. In this work, HITEC salt ( $NaNO_{3}-NaNO_{2}-KNO_{3}$ with 7-49-44 mol%, respectively) is used as a thermal-hydraulic surrogate fluid. The surrogate relationship is therefore based primarily on similarity in high-Prandtl-number behavior, not on exact matching of all thermophysical or chemical properties. Additionally, HITEC has a melting temperature of about 140°C whereas the melting temperature of FLiBe is around 450°C. The lower operating temperature of HITEC makes it easier to work with in laboratory settings, allowing shorter melting periods and a larger operating margin during freeze recovery. HITEC is also safer to use than FLiBe or FLiNaK due to the lack of beryllium and lower melting temperature. Important differences remain in density, viscosity, thermal conductivity, heat capacity, corrosion behavior, and chemical handling requirements; accordingly, the present results are interpreted as high-Prandtl-number natural-circulation measurements rather than direct one-to-one FLiBe performance predictions (Sohal et al., 2013).

Fig. 1. Prandtl number of different relevant salt compounds.

HITEC was selected during the prior development of the experimental facility following consideration of alternative molten-salt surrogate candidates. The selection was based primarily on achieving representative high-Prandtl-number thermal-hydraulic behavior while maintaining a sufficiently low melting temperature and practical laboratory handling requirements (see Fig. 1).

2.2. Facility

The main components of the facility are the loop with a transparent test section heater, melting pot with extension to allow for drainage and reuse of the salt, the external tape heaters, the PIV camera and laser setup, and the air heat exchanger on the cold leg and is illustrated with thermocouple locations in Fig. 2 (TW10 is fixed to the outside of the heat exchanger, and is primarily used during preheating and filling). The transparent heater is co-located with the optical test section, while external heaters on the opaque sections maintain the remaining loop and melting pot above the salt freezing temperature. The entire loop is covered in ceramic fiber insulation thick enough to minimize heat loss to the environment.

The loop has an inner diameter of 0.0254 m, and the length of each leg is 0.915 m. The test section is a quartz tube, 0.186 m long with an inner diameter of 0.0254 m. It is heated by running a current across stainless steel clamps on the outside of the quartz tube. This transparent heater allows for the flow visualization and acquisition of PIV measurements. The melting pot has two sections: the lower section is attached to the loop with a ball valve and compression fittings and is heated with 3 Inconel clam heaters. The top section connects to the bottom section with a quick clamp fitting and is heated with 4 Inconel clam heaters. A thermocouple is inserted into the melting pot to monitor the temperature of the salt as it melts and reaches operating temperature.

The heat exchanger is a shell and tube counter flow heat exchanger with an inner diameter of 0.051 m and a length of 0.305 m. A volumetric flow meter is connected between the shop pressurizer and the heat exchanger to read the flow rate of the air coming into the heat exchanger. Thermocouples also record the temperature of the air going in and out of the heat exchanger. Fig. 3 illustrates the layout of the top cooling section of the loop.

The loop is equipped with a data acquisition (DAQ) system that samples temperature measurements at 50 Hz. Seventeen K-type thermocouples were installed throughout the facility, consisting of six internal bulk-fluid measurements and eleven wall-mounted measurements. The internal thermocouples were mounted using compression fittings and the depth of was verified to be at the centerline of the pipe prior to loop construction. The wall thermocouples were mounted using stainless-steel hose clamps. All thermocouple locations are shown in Fig. 2. This description is complimentary with other descriptions in previous publications of this experimental facilities (Reis et al., 2024b,a; Carson, 2025).

2.3. Experimental procedures

Before the loop was filled, the test procedure began by heating the salt in the melting pot to $220^{\circ}$ C, and keeping it at that temperature while the loop walls were heated. To ensure that salt would not freeze when entering the loop, the walls were preheated to above $200^{\circ}$ C. The loop was then filled by opening the ball valve, and local heating was applied as necessary to establish flow through the loop.

The loops initial conditions were as follows: the hot leg was set to approximately 450 W, the volumetric flow rate of the heat exchanger was set to $7.993 \times 10^{3}$ m $^{3}$ /h (37 L/min), the test section was set to 50 W to offset the estimated heat lost through the test section. The loop was allowed to reach a steady-state condition with and remained for 18 h. It should be noted, the loop reached a stable condition before the end of the 18 h period.

It was noticed shortly after the 18 h, that the test section heater power supply had failed. This caused the temperatures in the loop to drop significantly in a short period of time (this will be discussed further in Section 4.2), and the velocity through the transparent section appeared to have decreased. The measurement was taken once the flow was determined to be unidirectional through the transparent test section. The test section was then able to be turned on again and the heat was set back to 50 W, which is approximately the heat loss to the environment. The PIV measurement was taken approximately 97 min after the test section increased. Again, the measurement was taken once the flow appeared to be uniform and unidirectional through the test section.

Fig. 2. Location of the thermocouples through the loop. $TB_{i}$ indicates a thermocouple measuring the bulk fluid temperature. $TW_{i}$ indicates the location of a thermocouple attached to the wall. The transparent test-section heater spans the 0.186 m quartz tube in the vertical leg between the stainless-steel electrical clamps; auxiliary external heaters are located on the opaque loop sections and melting-pot assembly used for preheating, filling, and maintaining salt inventory above the freezing point.

Fig. 3. Layout of the heat exchanger, location of the thermocouples, and flow direction of molten salt and air.

The final measurement was of the test section heater set to around 100 W. This measurement was taken only 20 min after the heat input was increased, and the flow appeared to be uniform through the test section. Due to the surface of the test section being in sub-optimal condition, the time the heater was left on the higher power was limited to preserve the integrity of the test section for future experiments.

Non-dimensional analyses are performed to present a flow regime identification and determine a trend in local and global non-dimensional parameters as the heat is added to the loop.

3. Methods

3.1. Particle Imaging Velocimetry (PIV)

Particle imaging velocimetry (PIV) is a noninvasive flow visualization technique that tracks the path of the illuminated particles entrained in the fluid with high-speed imaging. A continuous 10 W laser with a 542 nm wavelength laser plane was used to illuminate the particles of the fluid. An optical collimator was used to create the 1 mm thick laser plane that was aligned in the center of the test section. The PIV implementation in molten salt is constrained by high operating temperature, optical access through a curved quartz wall, reflection from the heater clamps and tube surface, and the need to maintain tracer-particle survivability and flow-following fidelity during natural circulation. The transparent heater was therefore used to preserve optical access while imposing a controlled local thermal boundary condition.

High-speed images were taken using a two camera setup and a beam splitter. The full field images were captured with a Phantom MIRO R311 with a complimentary metal oxide semi-conductor (CMOS). The camera semiconductor combination is capable of capturing data at 1-gigapixel per second. This camera used a Zeiss 50 mm lens and images were captured with a set resolution of $512 \times 800$ pixels with a frame rate of 250 fps.

A known weakness of PIV is that the uncertainty near the wall is not insignificant. To counter this, a near wall measurement was taken simultaneously with the full field images. To do this, a Photron FASTCAM NOVA S9 was used – coupled with a 200 mm lens – to capture images near the wall. The camera's resolution was $1024 \times 1024$ pixels and sampled at 1000 fps. The beam splitter ensured that both cameras were aligned at the same elevation and were seeing the same view of the test section; dividing the light between the two cameras.

The displacement of tracer particles between image frames was evaluated using the MATLAB-based PRANA PIV software suite. A multi-grid, multi-pass cross-correlation approach was implemented in conjunction with universal outlier detection (UOD) to identify and replace spurious velocity vectors (Reis et al., 2024b). The interrogation window sizes and overlap percentages employed in the UOD procedure are summarized in Table 1. Across all experimental conditions and both PIV configurations (full-field and near-wall), the proportion of identified erroneous vectors remained below 5%. This level of vector rejection is consistent with accepted PIV quality standards and aligns with prior in-house validation experience (Menezes et al., 2023).

An in-house calibration procedure was implemented to correct for radial optical distortion introduced by the quartz test section and refractive effects of the molten salt during post-processing of the PIV images (Reis et al., 2024b). The camera system was calibrated to focus on the geometric centerline of the tube, and the laser sheet was aligned with the tube center to minimize measurement bias. Because the spanwise velocity component was negligible relative to the streamwise component, optical corrections were applied primarily in the radial direction to reduce uncertainty in the near-wall measurements. PIV data quality was evaluated using tracer response, vector rejection rate, image correlation quality, and consistency with prior molten-salt measurements in the same facility. The simultaneous full-field and near-wall views were used to retain the loop-scale velocity distribution while resolving the region adjacent to the heated quartz wall.

The Stokes number, denoted as St, is a dimensionless parameter that characterizes the dynamic response of particles suspended in a fluid flow. It represents the ratio of particle inertial response time to a characteristic fluid timescale and is commonly used to assess whether tracer particles accurately follow fluid streamlines in Particle Image Velocimetry (PIV). The Stokes number is defined as

$$ S t = \frac {\tau_ {p}}{\tau_ {f}}\tag{1} $$

where $\tau_{p}$ is the particle relaxation time and $\tau_{f}$ is the characteristic fluid timescale.

For small, spherical particles in low Reynolds number (creeping or Stokes) flow, the particle relaxation time is given by

$$ \tau_ {p} = \frac {\rho_ {p} d _ {p} ^ {2}}{1 8 \mu}\tag{2} $$

where $\rho_{p}$ is the particle density (kg/m $^{3}$ ), $d_{p}$ is the particle diameter (m), and $\mu$ is the dynamic viscosity of the fluid (Pa s). This expression assumes Stokes drag, valid when viscous forces dominate over particle inertia.

The characteristic fluid timescale may be approximated using convective transport arguments as

$$ \tau_ {f} = \frac {L}{U}\tag{3} $$

where L is a characteristic length scale (m) and U is a characteristic velocity scale (m/s) of the flow.

Substituting Eqs. (2) and (3) into Eq. (1) yields

$$ S t = \frac {\rho_ {p} d _ {p} ^ {2} U}{1 8 \mu L}\tag{4} $$

This formulation makes explicit the dependence of St on both particle properties $(\rho_{p}, d_{p})$ and fluid properties $(\mu, U, L)$ .

When $St \ll 1$ , particles are strongly coupled to the fluid motion and closely follow streamlines. For $St \approx 1$ , particles exhibit measurable lag relative to the fluid velocity field. When $St \gg 1$ , particle inertia dominates and particles may cross streamlines or impact solid boundaries. For accurate PIV measurements, tracer particles should satisfy St < 0.1, ensuring adequate flow tracking fidelity (Raffel et al., 2007).

The uncertainty bounds presented in Fig. 4 were calculated by propagating the uncertainty in molten salt viscosity and the range of characteristic velocities measured in prior PIV experiments conducted in this facility (Reis et al., 2024b). Maximum and minimum velocity values were used to bound the fluid timescale, while reported thermophysical property uncertainty was used to estimate the corresponding variation in St.

The time-resolved PIV dataset provides two in-plane velocity components, U (streamwise) and V (spanwise). The instantaneous velocity magnitude is computed as

$$ U _ {\mathrm{mag}} = \sqrt {U ^ {2} + V ^ {2}}\tag{5} $$

This represents a two-dimensional slice of an inherently three-dimensional flow field. To obtain a physically meaningful bulk velocity for comparison with analytical models and non-dimensional parameters, a cross-sectional area-weighted average must be evaluated.

The radial coordinate associated with the PIV field is reconstructed by defining a radial vector corresponding to the right half of the measurement domain (from the pipe centerline to the wall). Assuming axisymmetric vertical pipe flow, the measured half-profile is revolved about the pipe centerline.

For each radial interval $r_{i-1} \rightarrow r_{i}$ , the differential annular area is

$$ \Delta A _ {i} = \pi \left(r _ {i} ^ {2} - r _ {i - 1} ^ {2}\right).\tag{6} $$

Table 1
Summary of window size and overlap used in particle image correlation.

Data setPass 1Pass 2Pass 3Overlap 1Overlap 2Overlap 3
Full Field $32 \times 64$ $32 \times 64$ $32 \times 64$ 50%75%86%
Near Wall $128 \times 128$ $128 \times 128$ $128 \times 128$ 50%75%86%

Fig. 4. The calculated Stokes number of HiTEC as a function of the temperature of the fluid.

The local velocity within each annulus is approximated using a trapezoidal average between adjacent radial nodes:

$$ U _ {i} = \frac {1}{2} \left[ U _ {\mathrm{mag}} (r _ {i}) + U _ {\mathrm{mag}} (r _ {i - 1}) \right].\tag{7} $$

The area-weighted contribution is accumulated as $U_{i}\Delta A_{i}$ , while the total area is accumulated as $\sum_{i}\Delta A_{i}$ . The resulting area-weighted mean velocity for the PIV-measured half-section is

$$ U _ {\mathrm{PIV,half}} = \frac {\sum_ {i} U _ {i} \Delta A _ {i}}{\sum_ {i} \Delta A _ {i}}.\tag{8} $$

Because only half of the pipe cross-section is explicitly integrated, the computed value is scaled to the pipe cross-sectional area. Let $ID_{g}$ denote the inner diameter of the glass (quartz) section and $ID_{ss}$ denote the inner diameter of the adjacent stainless-steel section. The full-section PIV-derived bulk velocity is then

$$ U _ {\mathrm{PIV}} = U _ {\mathrm{PIV,half}} \frac {\pi \left(\frac {I D _ {g}}{2}\right) ^ {2}}{\pi \left(\frac {I D _ {s s}}{2}\right) ^ {2}}.\tag{9} $$

This bulk velocity is used for comparison with analytical correlations, loop-integrated momentum balances, and Reynolds number evaluation. Correction for optical distortion introduced by the glass curvature and refractive effects was performed following the calibration methodology described in Reis et al. (2024b), ensuring accurate reconstruction of the bulk velocity through the transparent test section.

3.2. Heat exchanger performance

Heat exchanger performance was evaluated using the log-mean temperature difference (LMTD) method in tandem with the effectiveness-NTU framework for the counter-flow system configuration illustrated in Fig. 3. The instantaneous heat transfer was calculated from the air side as

$$ Q _ {a c t u a l} = \dot {m} _ {a i r} c _ {p, a i r} (T _ {c, o u t} - T _ {c, i n}) $$

(10)

where all relevant air properties were evaluated as temperature-dependent parameters, and the thermocouple measurement was assumed to be the bulk fluid temperature at its respective location. The molten salt heat capacity rate (Eq. (11)) was computed from the measured natural circulation mass flow rate and an averaged specific heat between inlet and outlet conditions. From both heat capacity rates of the hot and cold-side, the minimum,

$$ C _ {m i n} = m i n (\dot {m} c _ {p})\tag{11} $$

was identified and used to define the thermodynamic upper limit of heat transfer,

$$ Q _ {m a x} = C _ {m i n} (T _ {h, i n} - T _ {c, i n})\tag{12} $$

which in turn allows the heat exchanger effectiveness, $\varepsilon$ , to be expressed as

$$ \varepsilon = \frac {Q _ {\text {actual}}}{Q _ {\text {max}}}.\tag{13} $$

The log-mean temperature difference (LMTD) was determined using the inlet and outlet heat exchanger temperatures via the following equation:

$$ L M T D = \frac {\Delta T _ {1} - \Delta T _ {2}}{l n (\Delta T _ {1} / \Delta T _ {2})}\tag{14} $$

where $\Delta T_{1}$ and $\Delta T_{2}$ are defined as

$$ \Delta T _ {1} = T _ {h, i n} - T _ {c, o u t}\tag{15} $$

$$ \Delta T _ {2} = T _ {h, o u t} - T _ {c, i n}.\tag{16} $$

4. Results

4.1. Uncertainty quantification

Uncertainty in the PIV velocity field arises from three independent sources: calibration magnification error, pixel-displacement error, and timing uncertainty between correlated image frames. The instantaneous velocity components are obtained from particle displacement measurements as

$$ U = \frac {\Delta p _ {U}}{\Delta t} M,\tag{17} $$

$$ V = \frac {\Delta p _ {V}}{\Delta t} M,\tag{18} $$

where $\Delta p_{U}$ and $\Delta p_{V}$ are pixel displacements in the streamwise and spanwise directions, respectively, $\Delta t$ is the inter-frame time separation, and M is the magnification factor (m/pixel).

Assuming independent uncertainties in magnification $(\sigma_{M})$ , pixel displacement $(\sigma_{p})$ , and frame timing $(\sigma_{\Delta t})$ , linearized error propagation yields the velocity-component variance in root-sum-square (RSS) form:

$$ \sigma_ {U _ {i}} = \sqrt {(U _ {i}) ^ {2} \sigma_ {M} ^ {2} + \left(\frac {\Delta p}{\Delta t}\right) ^ {2} \sigma_ {p} ^ {2} + \left(U _ {i} \frac {\Delta p}{\Delta t}\right) ^ {2} \sigma_ {\Delta t} ^ {2}}.\tag{19} $$

An identical formulation is applied for $\sigma_{V}$ . These terms correspond to the calibration contribution, pixel-resolution contribution, and timing contribution, respectively. The uncertainty formulation follows the methodology outlined in Reis et al. (2024b) for both full-field and near-wall PIV measurements.

The uncertainty in the velocity magnitude,

$$ \sigma_ {U _ {\mathrm{mag}}} = \sqrt {\left(\frac {U}{U _ {\mathrm{mag}}}\right) ^ {2} \sigma_ {U} ^ {2} + \left(\frac {V}{U _ {\mathrm{mag}}}\right) ^ {2} \sigma_ {V} ^ {2}},\tag{20} $$

is obtained by propagation from the component uncertainties. Across the three cases, the heat-loss case had an average velocity magnitude uncertainty of 4.02%, the adiabatic case had an average velocity magnitude uncertainty of 1.97%, and the heat-addition case had an average velocity magnitude uncertainty of 1.29%. These values are consistent with previously reported PIV velocity-magnitude uncertainty for this molten-salt facility (Reis et al., 2024b). To determine the bulk-velocity uncertainty, the magnitude uncertainty is integrated over concentric annuli consistent with the area-weighted averaging procedure described previously:

$$ \sigma_ {U _ {\mathrm{PIV}}} = \frac {\sqrt {\sum_ {i} \sigma_ {A , i} ^ {2}}}{\sum_ {i} \varDelta A _ {i}}.\tag{21} $$

The resulting value is subsequently scaled by the ratio of glass-to-steel cross-sectional areas to match the hydraulic diameter of the loop. The normalized quantity $\sigma_{U_{PIV}}/U_{PIV}$ represents the total fractional uncertainty in the PIV-derived bulk velocity. Across the three cases, the heat loss case had a bulk-velocity uncertainty of 0.55%, the adiabatic case had a bulk-velocity uncertainty of 0.22%, and the heat addition case had a bulk-velocity of 0.16%.

Thermal measurements and thermophysical properties introduce additional uncertainty into the nondimensional parameters. Type-K thermocouples provide a temperature uncertainty $\sigma_{T}$ , which propagates into the buoyancy driving term as

$$ \sigma_ {\Delta T} = \sqrt {2} \sigma_ {T}.\tag{22} $$

Uncertainty in thermophysical properties $(\rho, \mu, c_{p}, \text{and } k)$ combines temperature-propagated error with the reported correlation uncertainty from the INL property database (Sohal et al., 2013). For a general property $f(T)$ ,

$$ \sigma_ {f} = \sqrt {\left(\frac {d f}{d T} \sigma_ {T}\right) ^ {2} + \left(s _ {f} f\right) ^ {2}},\tag{23} $$

where $s_{f}$ represents the reported fractional uncertainty of the property correlation. The reported uncertainties from the INL database are summarized in Table 2.

Table 2
Thermophysical property uncertainty reported by INL database (Sohal et al., 2013).

PropertyReported uncertainty (%)
Density (ρ)2
Viscosity (μ)16
Specific heat (cp)5
Thermal conductivity (k)5

4.2. Thermal analysis & flow regime identification

Natural circulation is a density driven flow with a heat source and a sink. During steady-state operation, the temperatures in the loop will average out, and the order of the temperatures will generally stabilize depending on their location. Fig. 5 illustrates the temperatures distributed in the loop for each test. As mentioned before, the test section is heated by passing a current over the section. If a current is not applied over the test section, heat is lost across the test section. The rate of heat loss over the test section between TB4 and TB5, depicted in Fig. 2, was calculated as approximately 50 W. The horizontal heater and horizontal heat exchanger sections were both brought up to a constant, stable, steady-state condition as aforementioned.

Fig. 6 summarizes the loop thermal state prior to each PIV measurement, with the mean of the temperature distribution shown in Fig. 5 and thermocouple locations presented in Fig. 2. Across all tests, the global differential temperature distribution is qualitatively similar (Fig. 5), indicating that the overall buoyancy driving and heat-rejection balance remain comparable between cases. Mainly, the temperature difference across the test section (between TB4 and TB5) consistently shows a local decrease, even when heater power is applied at levels intended to offset measured heat losses. This observation should not be interpreted as evidence that the global energy balance is violated. Instead, it indicates that the two discrete bulk thermocouple readings across the transparent section do not uniquely represent the local cross-sectional bulk temperature under transient, high-Prandtl-number conditions. The measured temperature difference can be affected by localized wall heating, heat loss through the transparent section, incomplete radial mixing, bend-induced redistribution upstream of the test section, thermal inertia of the quartz wall and clamps, and finite thermocouple placement. Therefore, the absence of a monotonic relationship between applied test-section heater power and the measured TB4–TB5 temperature rise is interpreted as a spatial-measurement limitation combined with localized thermal stratification, not as a failure of the loop-scale heat balance. Higher spatial resolution measurements are required to isolate these effects and determine the true local energy balance.

In the heat-loss test, with the test section heater off, a corresponding temperature drop is shown in Fig. 6(a) when heat was lost. During this period, the loop temperatures decreased steadily, confirming that the system was operating under net heat removal. A small temperature drop between TB4 and TB5 was again observed. In this configuration, the drop is likely due to either mixing, the buoyancy pathway of the hot fluid rising after the corner at TB3, or thermal losses through the test section. Taken together, these results point towards the temperature behavior across the test section reflecting a combination of external heat loss mechanisms and internal thermal evolution, rather than a simple correspondence between applied heater power and local fluid temperature rise.

The adiabatic test occurs when the test section heater was on, and the heat added to the test section was approximately equal to the heat lost across the test section ( $\approx$ 50 W). Although not quickly, Fig. 6(b) depicts the average temperature of the loop started rising again, approaching the same steady-state conditions as before the heater failed. In all cases, the PIV measurement was taken when the flow appeared to stabilize (i.e. sufficient time had passed for the fluid to circulate through the loop multiple times and become unidirectional if it was not prior).

Fig. 5. Temperature distribution through the loop plotted against thermocouple elevation. The plotted TP/TB designations correspond to the internal bulk-fluid thermocouple locations shown schematically in Fig. 2; specifically, TP1–TP5 denote the same bulk-fluid measurement sequence as TB1–TB5.

(a)

(b)

Fig. 6. The trend of the average of the loop internal thermocouple measurements 15-minutes prior to each PIV measurement: (a) heat loss; (b) adiabatic; (c) heat addition.
Table 3

The heat-addition test was conducted by adding $\approx100$ W across the test section, which was calculated as almost double the heat addition required to maintain an adiabatic case. Because of the variance of the power supply and condition of the test section due to previous experimental incidents, 100 W was the maximum power deemed acceptable to protect the integrity of the test section applying to the transparent section. As depicted in Fig. 6(c), the temperatures increase quicker than the temperatures in Fig. 6(b). This was expected because this was a 22% increase in total heater power (Fig. 5), although it was on the vertical leg rather than the horizontal leg.

The total electrical heater power delivered to the loop, denoted as $Q_{t}$ and the measured salt-side temperature decreases across the heat exchanger,

$$ Q _ {\mathrm{net}} = \dot {m} _ {s} c _ {p, s} \left(T _ {h, \text {in}} - T _ {h, \text {out}}\right),\tag{24} $$

where $\dot{m}_{s}$ is the salt mass flow rate calculated from the area-weighted average PIV velocity magnitude, and $c_{p,s}$ is the salt heat capacity evaluated at a representative bulk temperature. Using the measured temperatures $T_{h,in} \equiv TB6$ and $T_{h,out} \equiv TB1$ , the residual heat loss to the environment is then

$$ Q _ {\text {loss,meas}} = Q _ {t} - Q _ {\text {net}}.\tag{25} $$

This quantity aggregates all mechanisms not captured by Eq. (24), and is reported in Table 3.

Comparison of the calculated total system loss to the calculated heat removal through the heat exchanger.

Test caseCalculated system loss [W] ( $Q_{loss,meas}$ )Calculated heat removed [W] ( $Q_{HX,air}$ )
Heat loss76.3100.2
Adiabatic190.1100.9
Heat addition156.599.7

The heat exchanger heat removal inferred from the air temperature rise is

$$ Q _ {\mathrm{HX,air}} = \dot {m} _ {a} \overline {{c}} _ {p, a} \left(T _ {c, \text {out}} - T _ {c, \text {in}}\right),\tag{26} $$

where $T_{c,in} \equiv T_{HX,in}$ and $T_{c,out} \equiv T_{HX,out}$ are the measured air inlet/outlet temperatures and $\overline{c}_{p,a}$ is the air heat capacity (evaluated at the mean air temperature). Eq. (26) depends primarily on the volumetric flow rate and the measured air temperature rise, with model limited to the density conversion in the mass flow rate conversion and the choice of specific heat capacity for the air, $\overline{c}_{p,a}$ .

The measured thermal loss in Eq. (25) and the calculated heat exchanger heat removal in Eq. (26) do not match exactly. Eq. (24) assumes TB6 and TB2 represent bulk mixed temperatures. In high-Prandtl-number molten salts, thermal boundary layers can remain strongly stratified; centerline or discrete probe locations can therefore under- or over-represent the true cross-sectional bulk temperature. This directly biases both $Q_{net}$ and the residual heat loss, $Q_{loss,meas}$ .

Fig. 7. Log-mean temperature difference and heat exchanger effectiveness after loss of test section power.

Fig. 8. Log-mean temperature difference and heat exchanger effectiveness under adiabatic test section conditions.

Fig. 9. Log-mean temperature difference and heat exchanger effectiveness under high-power test section conditions.

Effectiveness was selected to further evaluate heat exchanger performance because it normalizes heat transfer relative to the thermodynamic upper limit (Eq. (12)), thereby removing trivial scaling with inlet temperature difference. In a natural circulation loop, the mass flow rate, and therefore the heat capacity rate (Eq. (11))—is not imposed but emerges from buoyancy–friction balance. Using dimensional heat duty alone therefore conflates changes in hydraulic driving with exchanger thermal performance. Analysis of the heat exchanger effectiveness evaluates how the exchanger utilizes the available temperature potential under dynamically varying flow conditions, while retaining sensitivity to the coupled thermalhydraulic response.

Across the three test cases, consistent inverse trends were observed between LMTD and heat exchanger effectiveness. Cases characterized by increasing bulk temperature and rising LMTD exhibited steady decline in effectiveness, while the opposite was true for decreasing bulk temperature and LMTD. These trends reflect a coupling between power input, buoyancy force, and heat exchanger utilization.

When excess power is introduced on the rising leg of the loop, the molten salt bulk temperature measurement increases, decreasing viscous forces and increasing the Reynolds number. This raises the hot-side heat capacity rate and reduces fluid residence time within the heat exchanger. Although measured temperature difference may increase under these conditions, the exchanger extracts a smaller fraction of the available heat, leading to the decreasing effectiveness seen in Fig. 9. In contrast, when power is reduced, bulk temperature and buoyancy head decrease, slowing circulation. The reduced mass flow increases residence time and enhances the fractional temperature drop through the heat exchanger, increasing effectiveness as in Fig. 7. As seen in Fig. 8, under conditions of stable power replacement, the LMTD and effectiveness both remain approximately constant, strengthening the coupling between input power and exchanger effectiveness.

Flow regime identification and non-dimensional analysis recast dimensional data into characteristic ratios that reveal dominant force balances and heat-transfer mechanisms, enabling scale-independent comparison. As shown in Fig. 10(a), the loop remains laminar across all tests, with observed trends primarily driven by inter-test temperature differences in density and viscosity, and an increase in salt velocity. Axial conduction through the pipe walls is neglected due to the combined thickness of the tubing and insulation.

The Reynolds number, Re, represents the ratio of inertial forces to viscous forces and calculated in Eq. (27). The parameters of the equation are: $\rho$ , which represents the fluid density in $(\mathrm{kg}/\mathrm{m}^{3})$ , U as the mean velocity measured through the full field PIV section (m/s), D which is the diameter of the test section (m), and $\mu$ which is the fluids dynamic viscosity (N s/m $^{2}$ ) The Reynolds number is the predominant characteristic number which in flow regime identification. Since the Reynolds numbers in Table 4 are all well below 2000 which indicates that the flow is laminar. From the results presented in Fig. 10(a), both globally and locally at the test section the Reynolds number increases as the heating condition of the test section increases.

$$ R e = \rho U D / \mu\tag{27} $$

The Prandtl number represents the ratio of viscous diffusion to thermal diffusion and the ratio of the momentum boundary layer and thermal boundary layer, and is calculated in Eq. (28). The parameters of the equation are: $\mu$ , the fluid dynamic viscosity (N s/m $^{2}$ ), $c_{p}$ , the specific heat capacity of the fluid (J/kg K), and $k$ , the thermal conductivity (W/m K). Molten salts in general have higher Prandtl numbers that many thermal fluids, indicating a relatively thick momentum boundary layer. That being said, as the heater power is increased, the Prandtl number decreases (Fig. 10(b)), indicating that thermal diffusivity increases. This means the heat spreads more quickly through the fluid, improving convective heat transfer over conduction.

$$ P r = \mu c _ {p} / k\tag{28} $$

The Grashof number, $Gr$ , represents the ratio of buoyant to viscous forces. The parameters of the equation are: $g$ , the acceleration of gravity $(\mathrm{m/s}^2)$ , $\beta$ is the coefficient of thermal expansion $(1/\mathrm{K})$ , $T_{Wall}$ is the wall temperature (K), $T_{Bulk}$ is the bulk fluid temperature (K), $L$ is the characteristic length (m), $u$ is the kinematic viscosity $(\mathrm{m}^3/\mathrm{s})$ . The Grashof numbers in this facility are very high, above $10^{9}$ (Table 4), which indicates strong natural convection. There is no apparent correlation with the Grashof number as the temperatures increase (Fig. 10(c)).

$$ G r = g \beta (T _ {W a l l} - T _ {B u l k}) L ^ {3} / u ^ {2}\tag{29} $$

The Nusselt number, Nu, represents the ratio of convective heat transfer to conductive heat transfer. The parameters of the equation are: h, the heat transfer coefficient $(W/m^{2}K)$ , D, the diameter of the pipe, (m), and $k_{f}$ , the fluid thermal conductivity. A Nusselt number greater than 1 indicates that convection dominates. From Table 4, the fluid indicates that convective heat transfer highly dominates. From Fig. 10(e), as the temperature of the fluid increases so does the magnitude of the Nusselt number and strength of the convective heat transfer. Previous work showed that the average laminar flat-plate correlation provides reasonable agreement with measured molten-salt Nusselt numbers in the developing regime (Reis et al., 2024b). While derived for external flow, its $Re^{1/2}Pr^{1/3}$ scaling captures the dominant near-wall boundary-layer behavior present in high–Prandtl-number molten-salt flow. Accordingly, Eq. (31) is used here as a first-order estimate of the Nusselt number.

$$ N u = h D / k _ {f}\tag{30} $$

Test Section Power Input [W]

Test Section Power Input [W]
Fig. 10. Comparison of the global and local characteristic numbers. The images from top left to bottom right ((a)–(f)): (a) Reynolds number, (b) Prandtl number, (c) Grashof number, (d) Stanton number, (e) Nusselt number, (f) Rayleigh number.

$$ N u = 0. 6 6 4 R e ^ {0. 5} P r ^ {0. 3 3}\tag{31} $$

The Rayleigh number, Ra, characterizes the onset and intensity of natural convection. It represents a balance between buoyancy driven flow and the opposing effects of viscosity and thermal diffusion. In the case of this facility, a high Rayleigh number is present near the order of $10^{10}$ (Table 4). This indicates a strong buoyancy driven flow, but like the Grashof number, does not expose a strong correlation as the temperature increases.

$$ R a = G r P r\tag{32} $$

The Stanton number, St, represents the ratio of heat transferred to the fluid to the heat retained by the fluid. With the Stanton number much less than 1 (Table 4), this indicates that heat transfer is relatively slow compared to the fluid motion, meaning thermal energy is not instantly transferred to the surroundings. Small St supports large thermal boundary layers relative to the velocity boundary layer, which correlates with high Prandtl-number fluids. Fig. 10(d) expresses the Stanton number continues to decrease as the temperature increases. The lower St also suggests that more heat remains in the bulk fluid before being convected away, leading to increased heat retention in the flow.

$$ S t = N u / R e P r\tag{33} $$

These non-dimensional numbers characterize the flow behavior in the natural circulation loop as temperature increases. As the fluid temperature rises, the flow velocity generally increases; however, the fluid's ability to transfer heat decreases. In Fig. 10 and Table 4, global and local parameters are calculated. The global parameters are calculated based on the average temperature of the loop and the local parameters are calculated based on the average temperature of the fluid at the inlet and outlet of the quartz test section.

4.3. Velocity measurements

The full-field velocity contour plots are included in Fig. 11. For the heat-loss case the maximum velocity is approximately 0.03 m/s. For the adiabatic case, the maximum velocity is approximately 0.055 m/s. For the locally heated case, the maximum velocity is approximately

0.07 m/s. This trend is consistent with the full-field results previously reported for this facility (Reis et al., 2024b); as the Prandtl number decreases, the measured velocity increases. This is likely due to the decrease in viscosity as well as the decrease in density.

However, in Reis 2024 the full field velocity profiles for molten salt had two distinct peaks (Reis et al., 2024b). The measurements presented in this work have not yet reached a steady-state. As the fluid travels further up y-axis, the velocity peak drifts further to the right as is shown in Fig. 12. This illustrates that the flow has not yet reached a fully stable condition. Further, it had been observed in this test and previous tests that as the loop reached a steady-state condition, the peak location would oscillate from one side to another over a period of several hours. In some cases, the velocity profile similarly resembles the double-peak velocity profile in Reis et al. (2024b) after sufficient time spent at that steady state. Other factors may also influence the presence of the two-peak velocity profile that are not explored in this study. Further investigation is required to explain this hydraulic behavior. In the heat loss case in Fig. 11(a), the velocity skews further to the right more drastically than the other two cases, especially between 30 mm to 80 mm up the y-axis and up to 5 mm on the x-axis. This is due to the local heat loss at the test section. Although the St is so low, heat loss is significant enough to cause the velocity to shift.

A near-wall non-dimensional analysis of the velocity profile provides a framework for assessing whether the local shear dynamics are consistent with canonical wall-bounded flow behavior. By normalizing velocity with the friction velocity, $u_{\tau}$ , and distance from the wall with the viscous length scale, $u/u_{\tau}$ , the velocity field can be evaluated independent of absolute flow rate and bulk temperature variations. This approach isolates the balance between viscous stresses and inertial effects in the immediate vicinity of the wall, where momentum diffusion governs the structure of the boundary layer. In high-Prandtl-number molten salts, where viscosity varies strongly with temperature, such scaling is particularly valuable for identifying deviations from classical viscous sublayer behavior and for determining whether thermal-property gradients influence near-wall shear. Comparing the experimental profiles to the expected linear relation in inner scaling therefore provides a physics-based consistency check on both the flow regime and the inferred wall shear stress.

Fig. 13 depicts the non-dimensional near-wall velocity profiles. $U^{+}$ is the non-dimensional shear velocity, and $x^{+}$ is the non-dimensional distance from the wall. The profiles do not collapse exactly onto the canonical relation $U^{+} = x^{+}$ in the expected viscous-sublayer region, and the comparison should therefore be interpreted as a diagnostic of near-wall behavior rather than direct validation of a fully resolved viscous sublayer. Temperature-dependent viscosity near the heated wall may also alter the local viscous length scale, so using a bulk or locally averaged viscosity can bias both $x^{+}$ and $U^{+}$ under heat-addition conditions. In all three cases, the slope of $U^{+}$ is relatively close between cases, with the adiabatic and heated cases extending closer to the wall than the heat-loss case.

Table 4
Table of the global and local non-dimensional parameters for each data set.

Test caseGlobal ReLocal ReGlobal PrLocal PrGlobal GrLocal Gr
Heat loss13611218.417.6 $3.676 \times 10^9$ $9.677 \times 10^8$
Adiabatic28923817.816.9 $3.273 \times 10^9$ $1.689 \times 10^9$
Heat addition45537416.916.2 $4.512 \times 10^9$ $7.196 \times 10^8$
Global StLocal StGlobal NuLocal NuGlobal RaLocal Ra
Heat loss $8.1 \times 10^{-3}$ $9.2 \times 10^{-3}$ 20.318.1 $6.776 \times 10^{10}$ $1.698 \times 10^{10}$
Adiabatic $5.7 \times 10^{-3}$ $6.5 \times 10^{-3}$ 29.226.1 $5.817 \times 10^{10}$ $2.854 \times 10^{10}$
Heat addition $4.7 \times 10^{-3}$ $5.3 \times 10^{-3}$ 36.032.2 $7.627 \times 10^{10}$ $1.164 \times 10^{10}$

Fig. 11. Contour plots depicting the full velocity field over the transparent test section between the stainless steel clamps. From left to right: (a) heat loss case; (b) adiabatic case; (c) heated case.

(a)

(b)

(b)

Fig. 12. Radial velocity profile at three axial heights from full-field PIV results of each salt test. From left to right: (a) heat loss case; (b) adiabatic case; (c) heated case.

The final points of Fig. 13 in the adiabatic and heat-addition profiles should be interpreted with caution because they occur near the outer limit of the reliably resolved near-wall PIV region. At these locations, finite spatial resolution and uncertainty in the local wall-normal position can affect the inner-scaled velocity. In addition, $x^{+}$ depends on the friction velocity and kinematic viscosity used for the inner scaling, so uncertainty in these quantities can be amplified at larger wall-normal distances. The deviation of the final points from $U^{+} = x^{+}$ is therefore not interpreted as definitive evidence of a departure from canonical viscous-sublayer behavior.

As the Pr and St decrease, with a high Pr and a low St, measurements of the velocity boundary layer become increasingly valuable. Since the thermal boundary layer was not measured, the correlation relating the Pr with the ratio of the momentum boundary layer and the thermal boundary layer can yield information about the thermal boundary layer with a measured value of the momentum boundary layer. From a near wall measurement of the velocity near the boundary, this information becomes more readily available.

Fig. 13. Non-dimensional near wall velocity profile at Y/H = 0.5 for each test section heating condition.

5. Conclusions

An electrically heated transparent test section was utilized to visualize the flow of HiTEC molten salt $\left(\mathrm{NaNO}_{3}-\mathrm{NaNO}_{2}-\mathrm{KNO}_{3}\right)$ in a natural circulation loop through PIV measurements. A flow regime identification was presented, and heat-transfer characterization and heat-exchanger analyses were performed from non-dimensional numbers. From the flow regime identification, the system is in a natural-convection-dominated regime since Gr and Ra are both very large while Re is very low. Strong buoyant forcing enhances heat transfer and can produce localized unsteadiness or mixed-convection behavior even when the loop-averaged Reynolds number remains laminar.

PIV velocity results are presented for HiTEC. Although the loop had not reached a steady-state condition, the mean velocity profiles during transients are presented. As the measured bulk temperature and total heat input to the loop increases, the circulation velocity correspondingly increases. Further investigation is required to determine the comprehensive behavior of the salt hydraulics and thermal behavior in the adiabatic rising region.

The near-wall measurements indicate boundary-layer stretching and systematic changes in the inner-scaled velocity profiles with test-section heating. However, the profiles do not fully recover the canonical $U^{+} = x^{+}$ trend, so they should be interpreted as comparative near-wall measurements rather than definitive validation of a fully resolved viscous sublayer. With the high value of Ra in conjunction with boundary-layer stretching into the buffer-layer range, the higher heater-power condition exhibits localized transitional or mixed-convection characteristics even at low loop-averaged Re.

It is noted that as the Pr decreases, so does the point at which the velocity gradient begins to shift (Fig. 13). This indicates a slight decrease in the momentum boundary layer. Because the thermal boundary layer was not directly measured and the near-wall PIV resolution is finite, the results cannot definitively establish developing thermal boundary-layer behavior.

These findings have direct implications for how natural-circulation molten-salt systems are interpreted and modeled. Although the flow remains nominally low-Re, the combination of high Ra and evolving near-wall behavior indicates that heat transfer and momentum transport are governed by localized boundary-layer dynamics rather than bulk flow assumptions. Consequently, commonly used reduced-order approaches that rely on bulk temperature differences may misrepresent both the driving buoyancy and the resulting flow response. This reinforces the need for measurement-informed modeling strategies that account for spatially evolving thermal gradients and their influence on circulation, particularly for validation of system codes and design of passive heat removal systems.

CRediT authorship contribution statement

Thomas Carson: Writing – review & editing, Writing – original draft, Visualization, Methodology, Investigation, Funding acquisition, Formal analysis, Data curation. Hansol Kim: Writing – review & editing, Visualization, Investigation, Formal analysis. Joseph Seo: Writing – review & editing, Visualization, Methodology, Investigation, Formal analysis. Theodore Kupper: Writing – review & editing, Writing – original draft, Formal analysis. Cole Gentry: Writing – review & editing, Writing – original draft, Investigation. Kevin Clarno: Writing – review & editing, Writing – original draft, Investigation.

Declaration of Generative AI and AI-assisted technologies in the writing process

During the preparation of this work, the author(s) used ChatGPT by OpenAI in order to transform some unstructured initial thoughts and excerpts from experimental logs into coherent and structured sentences. After using this tool, the author(s) reviewed and edited all generated content and take(s) full responsibility for the content of the published article.

Declaration of competing interest

The authors declare no competing interests.

Acknowledgments

This study is supported by a subgrant from the University of Texas at Austin and partially funded by Texas Thorium LLC. The authors would like to acknowledge the help of Dr. Jadyn Reis for her expertise and assistance, especially during the experimental operation. The authors would also like to acknowledge the continued assistance of Reagan Spenrath for his assistance in continuing experiments.

Data availability

Data will be made available on request.

References

Abou-Jaoude, A., Walker, S.A., Bhaskar, S., Ji, W., 2021. Feasibility assessment of a natural-circulation salt irradiation loop in the advanced test reactor. Nucl. Technol. 207 (12), 1821–1841.

American Nuclear Society, 2024. Nuclear Safety Design Criteria and Functional Performance Requirements for Liquid-Fuel Molten Salt Reactor Nuclear Power Plants (ANSI/ANS-20.2-2023). American Nuclear Society.

Battistini, A., Cammi, A., Lorenzi, S., Colombo, M., Fairweather, M., 2021. Development of a CFD–LES model for the dynamic analysis of the DYNASTY natural circulation loop. Chem. Eng. Sci. 237, 116520.

Benzoni, G., Introini, C., Missaglia, A., Wang, X., Cammi, A., 2024. Sensitivity analysis on the DYNASTY facility 1D modelica models with the DAKOTA-FMU approach. Prog. Nucl. Energy 155, 104486.

Britsch, K., Anderson, M., Brooks, P., Sridharan, K., 2019. Natural circulation FLiBe loop overview. Int. J. Heat Mass Transfer 134, 970–983.

Carson, T., 2025. Conditions for bubble recirculation in a molten salt natural circulation loop and heater failure effect on loop conditions and argon bubble dynamics. Nucl. Eng. Des.

Creveling, H.F., De Paz, J.F., Baladi, J.Y., Schoenhals, R.J., 1975. Stability characteristics of a single-phase free convection loop. J. Fluid Mech. 67 (1), 65–84.

Fierro Lopez, A.N., Giudicelli, G., Tano Retamales, M., Rozak, E., Clarno, K.T., 2025. Validation of pronghorn for molten salt natural-circulation loops. Trans. Am. Nucl. Soc. 133 (1), 64–67.

Jeong, Y.S., Seo, S.B., Bang, I.C., 2018. Natural convection heat transfer characteristics of molten salt with internal heat generation. Int. J. Therm. Sci. 129, 181–192.

Kim, K., 2023. A study on licensing requirements for a non-light water micro-reactor in Korea. In: Transactions of the Korean Nuclear Society Spring Meeting. Jeju, Korea.

Krishnani, M., Basu, D.N., 2017. Computational stability appraisal of rectangular natural circulation loop: Effect of loop inclination. Ann. Nucl. Energy 107, 17–30.

Kudariyawar, J.Y., Srivastava, A.K., Vaidya, A.M., Maheshwari, N.K., Satyamurthy, P., 2016. Computational and experimental investigation of steady state and transient characteristics of molten salt natural circulation loop. Appl. Therm. Eng. 99, 560–571.

Kumar, N., Doshi, J.B., Vijayan, P.K., 2011. Investigations on the role of mixed convection and wall friction factor in single-phase natural circulation loop dynamics. Ann. Nucl. Energy 38 (12), 2247–2270.

Magnusson, J., Memmott, M., Munro, T., 2020. Review of thermophysical property methods applied to fueled and un-fueled molten salts. Ann. Nucl. Energy 146, 107608.

Menezes, C., Melsheimer, T., Pyle, D.W., Kinsky, M., Hassan, Y.A., 2023. Flow characteristics within an interior subchannel of a 61-pin wire-wrapped hexagonal rod bundle with a porous blockage. Phys. Fluids 35, 027106.

Misale, M., 2014. Overview on single-phase natural circulation loops. In: Proceedings of the International Conference on Advances in Mechanical and Automation Engineering. pp. 1–11.

Missaglia, A., Benzoni, G., Introini, C., Ricotti, M.E., Cammi, A., Foulon, F., 2025. Modeling and validation of the DYNASTY natural circulation loop with the RELAP5 code. Nucl. Eng. Des.

Nadella, S., Srivastava, A.K., Maheshwari, N.K., 2018. A semi-analytical model for linear stability analysis of rectangular natural circulation loops. Chem. Eng. Sci. 192, 892–905.

Nair, A.R., Shanmughom, R., Gopalakrishnan, R., Nair, A.A.S., 2019. Influence of bidirectional inclination on the stability of single-phase natural circulation loop. AIP Conf. Proc. 2134 (1), 030006.

Novarese, E., Benzoni, G., Introini, C., Lorenzi, S., Savoldi, L., Cammi, A., 2024. Stability analysis on two single-phase coupled natural circulation loops. Int. J. Heat Mass Transfer 232, 125886.

Raffel, M., Willert, C., Wereley, S., Kompenhans, J., 2007. Particle Image Velocimetry: A Practical Guide. Springer, Berlin.

Reis, J., Hassan, Y., 2025. Sam code validation for high Prandtl number flow in molten salt natural circulation facility. Nucl. Technol.

Reis, J., Seo, J., Hassan, Y., 2024a. Consequences of molten salt solidification in a natural circulation flow visualization loop due to heater failure. Nucl. Eng. Des. 424, 113278.

Reis, J., Seo, J., Hassan, Y., 2024b. Molten salt flow visualization to characterize boundary layer behavior and heat transfer in a natural circulation loop. Phys. Fluids 36, 033605.

Schultz, R.R., Crane, R.L., 2012. Development of a standard for verification and validation of software used to calculate nuclear system thermal fluids behavior. In: Proceedings of the International Conference on Nuclear Engineering. pp. 1–8.

Sohal, M.S., Ebner, M.A., Sabharwall, P., Sharpe, P., 2013. Engineering Database of Liquid Salt Thermophysical and Thermochemical Properties. Idaho National Laboratory Report, INL/EXT-10-18297, http://dx.doi.org/10.2172/1086824.

Srivastava, A.K., Kudariyawar, J.Y., Borgohain, A., Jana, S.S., Maheshwari, N.K., Vijayan, P.K., 2015. Experimental and theoretical studies on the natural circulation behavior of molten salt loop. Appl. Therm. Eng. 98, 513–521.

Srivastava, A.K., Saikrishna, N., Maheshwari, N.K., 2022. Steady state performance of molten salt natural circulation loop with different orientations of heater and cooler. Appl. Therm. Eng. 218, 119318.

U.S. Department of Energy, Idaho National Laboratory, 2024. Nuclear Facility Licensing and Authorization by NRC and DOE. Idaho National Laboratory.

U.S. Nuclear Regulatory Commission, 2005. Regulatory Guide 1.203: Transient and Accident Analysis Methods. U.S. NRC, Washington, DC.

U.S. Nuclear Regulatory Commission, 2018. Regulatory Guide 1.232, Rev. 0: Guidance for Developing Principal Design Criteria for Non-Light-Water Reactors. U.S. NRC, Washington, DC.

U.S. Nuclear Regulatory Commission, 2020. Regulatory Guide 1.233, Revision 0: Guidance for a Technology-Inclusive, Risk-Informed, and Performance-Based Methodology to Inform the Licensing Basis and Content of Applications for Non-Light Water Reactors. U.S. NRC, Washington, DC.

Vijayan, P.K., 2002. Experimental observations on the general trends of the steady state and stability behaviour of single-phase natural circulation loops. Nucl. Eng. Des. 215, 139–152.

Vijayan, P.K., Austregesilo, H., 1994. Scaling laws for single-phase natural circulation loops. Nucl. Eng. Des. 152 (3), 331–347.

Villarreal, T.R., 2025. Development and Evaluation of a Machine Learning-Enhanced Drift-Flux Model in Molten-Salt Bubbly Flow (Ph. D. Dissertation). The University of Texas at Austin.

Villarreal, T.R., Rozak, E.R., Clarno, K.T., Hassan, Y.A., 2024. An integrated operation and simulation approach for design and analysis of molten salt-based systems. http://dx.doi.org/10.13182/T131-45903.

Zhang, S., Lin, H.-C., Sun, X., 2023. Thermal-hydraulic system-level analysis of a molten salt natural circulation loop. Nucl. Sci. Eng. 197 (5), 920–946.

Zhang, S., Sun, X., 2023. Mixed convective and radiative heat transfer of LiF-BeF $_{2}$ -ThF $_{4}$ -UF $_{4}$ in a vertical circular tube. Ann. Nucl. Energy 185, 109706.

Zou, L., Hu, G., O'Grady, D., Hu, R., 2021. Code validation of SAM using natural-circulation experimental data from the compact integral effects test (CIET) facility. Nucl. Eng. Des. 377, 111144.

专家评价结论

暂无专家评价

登录后可给出价值判定。

基础信息

来源分类 论文
来源名称 熔盐堆论文文献(2026)
署名来源 Thomas Carson、Hansol Kim、Joseph Seo、Theodore Kupper、Cole Gentry、Kevin Clarno、Yassin Hassan
发布时间 日期不详
AI建议价值定级 高价值
标签
熔盐堆 自然循环 热工水力 PIV测速 边界层 被动排热
AI抽取状态 已抽取 · 2026-09-24 14:58
原文链接 https://scholar.google.com/scholar?q=...
创建时间 2026-09-24 14:57
更新时间 2026-09-24 14:57

价值评价

登录后可进行价值评价。